Experience In Motion
USER INSTRUCTIONS
Installation
Operation
Maintenance
Limitorque Actuation Systems
Modutronic 20 II
FCD LMENIM4002-00 – 08/06 (Replaces 401-12000)
Zobrazit stránku 0
1 2 3 4 5 6 ... 31 32

Shrnutí obsahu

Strany 1 - USER INSTRUCTIONS

Experience In MotionUSER INSTRUCTIONSInstallationOperationMaintenanceLimitorque Actuation Systems Modutronic 20 IIFCD LMENIM4002-00 – 08/06 (Replaces

Strany 2 - Contents

Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/06103 DefinitionsFigure 3.1 – Calibration PositionsCommand Signal Input signal p

Strany 3

11Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/06flowserve.com4 Initial Checkout and Setup4.1 Verify Correct Motor Rotation

Strany 4

Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/0612Single-Phase Motor1. Using the Handwheel, move the valve to a midtravel pos

Strany 5 - Introduction

13Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/06flowserve.comFigure 4.2 – Standard Motor Rotation and Reverse Motor Rotation

Strany 6 - 1.4 Product Features

Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/0614Figure 4.3 – Potentiometer Calibration Components Shown on a LY Position In

Strany 7 - 1.5 Product Specifications

15Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/06flowserve.comTable 4.1 – Modutronic 20 II Terminal ConnectionsMod 20 II Term

Strany 8 - Operation

Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/06165 Mod 20 II PresetsWARNING: Hazardous Voltage. Turn power OFF before removin

Strany 9

17Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/06flowserve.com3. Rotate OFF TIME Potentiometer 8 turns CW z.4. This will pro

Strany 10 - Definitions

Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/06186 Calibration ProcedureWARNING: Hazardous Voltage in Control Compartment. E

Strany 11 - Initial Checkout

19Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/06flowserve.com3. To simulate a command signal, connect the mA Calibrator to t

Strany 12

Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/062Contents1 Introduction 51.1 Safety Information 51.2 Product Identificati

Strany 13 - Feedback Potentiometer

Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/0620Table 6.1 – DIP Switch Setting Levels of Deadband AccuracyDeadband Percentag

Strany 14

21Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/06flowserve.coma. Set the mA Calibrator to the maximum command signal (normall

Strany 15 - flowserve.com

Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/06221. If the actuator hunts upon reaching the new set-point, reduce the GAIN c

Strany 16 - Mod 20 II Presets

23Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/06flowserve.com7 TroubleshootingSymptom Possible Cause Corrective ActionUnit wi

Strany 17

Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/0624Symptom Possible Cause Corrective ActionUnits run in one direction only 1. S

Strany 18 - Calibration

25Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/06flowserve.com8 Wiring Diagram

Strany 19

Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/0626Figure 8.1 – Modutronic 20 II Typical Three-Phase Wiring DiagramG Green in

Strany 20

27Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/06flowserve.comFigure 8.1 – Modutronic 20 II Typical Three-Phase Wiring Diagram

Strany 21

Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/06289 Schematic

Strany 22

29Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/06flowserve.comFigure 9.1 – Modutronic 20 II Schematic DiagramR1CW3.74K-15 VDC2

Strany 23 - Troubleshooting

3Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/06flowserve.comFiguresFigure 1.1 – Modutronic 20 II 6Figure 2.1 – LY with a Mod

Strany 24

Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/0630Figure 9.1 – Modutronic 20 II Schematic Diagram (continued)RESETCONT V4TRIGR

Strany 25 - Wiring Diagram

31Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/06flowserve.com

Strany 26 - Green/white

flowserve.comTo find your local Flowserve representative:For more information about Flowserve Corporation, visit www.flowserve.com or call USA 1 800 22

Strany 27

Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/064

Strany 28 - Schematic

5Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/06flowserve.com1 Introduction1.1 Safety InformationThis Installation and Maint

Strany 29

Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/0661.2 Product IdentificationFigure 1.1 – Modutronic 20 II1.3 Product Descrip

Strany 30

7Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/06flowserve.com1.5 Product SpecificationsTable 1.1 – Modutronic 20 II Specificat

Strany 31

Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/0682 OperationThe Modutronic 20 II receives an input signal, normally 4-20 mA, f

Strany 32

9Limitorque Actuation Systems Modutronic 20 II FCD LMENIM4002-00 – 08/06flowserve.comFigure 2.1 – LY with a Modutronic 20 II and Associated Actuator C