2.2 Menu Tree
C-PRO & C-MOD Menu Tree - SW120
Basic Menu* Standard* 1 (Pos*/Alarm) Show alarm
Turns 2 (Pos*/Alarm) Deviation
Manual 3 (Pos/Alarm*) Limit 1
Calibrate Rotation Mid Pos 4 (Pos/Alarm*) Limit 2
Outputs ALARMS Torque
AutoCal Compa temp
Expert Cal Set Point Model Motor temp
Transm Open
Set Up Pro Torque Closed
Speed
Direction Open Speed
Curr Limit CCW/CW Close Speed
Status 0 0 Service N cycles Lo MotrVlt
IN Service* Pos Acc travel MotrTmpOOR
Set & Pos* Mean dev MotrOvrTrq
Protection NO* Set & Dev # of reset IGBT Open
YES Enter Code Torque Run time HallldxCrt
motor temp Extreme Temp PMCB Reset
Shift Basic Menu* comp temp Histogram HallldxLmp
Full Menu show LCS Pos graph BakEMFFaul
Read Statistics Reset stats IRAM Fault
Diagnostic HWOverTorq
Man/Auto AUT, OK=MAN MAN,OK=AUTO COP Fault
IGBT Short
Full Menu
Shift Basic Menu
Full Menu
Setup Full
linear*
Character equal %
quick open
custom
sqr root
# of points
Custom char custom curve
0% = 4.0mA*
Current range 100% = 20.0mA* free*
cutoff free* Cutoff Low LO = 1.0%
Set low limited cutoff Cutoff High HI = 99.0%
Trvl ctrl Set high limited Limit Low LO = 0.0%
Values Limit High HI = 100.0%
Direct
Transmitter Direction Reverse Position
Pos/Set Setpoint
Setpoint %*, mA, degrees
Position %*, degrees Position
Language Torque Nm, Lb-in*, Lb-Ft Set & Pos*
Appearance Units Temp C, F*, K Set & Dev
Default Display Menu
Start Logo On*/OFF
Orientation Normal*,Flipped
HW rev Message
SW rev Tag
Devicedata Capability Descriptor
HART/MBUS Date
Device ID ID = XXXXXX (= serial no)
Modbus adr ADDR = XXX
Assembly No.
Tuning Close Time MIN = 0.0s Universal Cmd Rev
Open Time MIN = 0.0s Special Cmd Rev
Deadband D = 1.0% Burst
Expert
Control PID Parameters
Stroketime CCW = X.Xs
CW = Y.Ys
FACT SET (press OK for 3 seconds to set default settings)
Read
MAN/AUTO
Calibrate Duplicated - see Basic Menu tree
Setup Pro
Status
Protection
Note: (*) indicates factory default setting
Slow shaft detection percentage
Unit address
C-MOD Dedicated
Character
Custom char
Current range (split range)
Trvl ctrl
Loss of setpoint signal position
Loss of setpoint signal time
Setpoint selector
Loss of position feedback action