FAULT SYMPTOM
Pump overheats and seizes
Bearings have short life or are damaged
Pump vibrates or is noisy
Mechanical seal has short life
Mechanical seal leaks excessively
Pump requires excessive power
Pump loses prime after starting
Insufficient pressure developed
Insufficient capacity delivered
Pump does not deliver liquid
PROBABLE CAUSES PROBABLE REMEDIES
Internal misalignment due to improper repairs
causing impeller to rub.
Check method of assembly, possible damage or
state of cleanliness during assembly.
Remedy or CONSULT FLOWSERVE, if
necessary.
Excessive thrust caused by a mechanical
failure inside the pump.
Check wear condition of impeller, its clearances
and liquid passages.
Oil has deteriorated. Change to new oil.
Kind of oil is not suitable. Change to suitable oil.
Lack of lubrication for bearings.
Check hours run since last charge of lubricant,
the schedule and its basis.
Lubricating oil supply pressure is too low.
Check oil unit and lubricating orifice.
CONSULT FLOWSERVE.
Improper installation of bearings (damage
during assembly, incorrect assembly, wrong
type of bearing etc).
Check method of assembly, possible damage or
state of cleanliness during assembly and type of
bearing used. Remedy or CONSULT
FLOWSERVE, if necessary.
Damaged bearings due to contamination.
Check contamination source and replace
damaged bearings.
C. MOTOR ELECTRICAL PROBLEMS
Wrong direction of rotation. Reverse 2 phases at motor terminal box.
Motor running on 2 phases only. Check supply and fuses.
Motor running too slow.
Check motor terminal box connections and
voltage.