Flowserve MX Limitorque Uživatelský manuál Strana 137

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 164
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 136
129
Limitorque MX Maintenance and Spare Parts FCD LMENIM2314-00 – 07/08
flowserve.com
STEP 4
Disconnect the three terminal block wires from l1, l2 and l3 on reverser as shown by loosening the
reverser screws.
Remove the 19 amp controls assembly (1-19) by loosening the three M4 mounting plate screws
(8-7) and slightly rotating the controls assembly counterclockwise (CCW) direction until the keyhole
slots in the baseplate allow the heads of the screws to pass through the baseplate.
Disconnect the two 2-pin white connectors from the lead seal.
STEP 5
Remove the 19 amp controls assembly (1-19)
by loosening the three M4 mounting plate
screws (8-7) and slightly rotating the controls
assembly counterclockwise (CCW) direction
until the keyhole slots in the baseplate
allow the heads of the screws to pass through
the baseplate.
Disconnect the two 2-pin white connectors
from the lead seal.
1-19
8-7
5
5.12.2 Remounting
Remount 19 amp power assembly by reversing the steps for removal.
5.13 Encoder (Through hole and surface mount
technology, most units prior to September 2007)
Table 5.10 – Encoder Parts List
Part Number Description Qty.
1-6 Encoder assembly 1
1-36 Socket head cap screw (M4x16) 3
6-11 Input gear, 78-tooth (ID 3 through 8) 1
6-24 Input gear, 69-tooth (ID 1 or 2) 1
Zobrazit stránku 136
1 2 ... 132 133 134 135 136 137 138 139 140 141 142 ... 163 164

Komentáře k této Příručce

Žádné komentáře