4.7 Slide retaining bolts through the rear face of the adapter plate and screw into
seal ange/gland. Evenly tighten retaining bolts to pull the seal into the adapter
t. See Figure 7.
Draw Cartridge into Adapter Using Attachment Bolts Figure 7
With the Spacer Ring Removed
Evenly Tighten Flange/Gland Bolts
to Start the Seal into the Adapter
Insert the Spacer Ring and
Continue Even Tightening
of the Bolts until the
Flange/Gland is Properly Seated
4.8 Once the seal ange/gland has started into the adapter t, remove the retaining
bolts and insert the spacer ring. Continue even tightening of the bolts until the
seal ange/gland is properly seated. See Figure 7. Some seals do not require
the use of the spacer rings; consult job drawing.
4.9 If seal is directly mounted on shaft and not on the pump sleeve install impeller
spacer hook sleeve (possibly modied), impeller, and suction cover.
4.10 Make any necessary impeller adjustments.
Important: Loosen bearing assembly and drive belts only enough to make
adjustment. Fully tighten bearing assembly bolts after adjustment.
Torque Value Chart N-m (ft-lb) Figure 8
Split Clamp/ Group 4-5 Taper
Drive Cap Ring Clamp/ Drive Collar
Screws Drive Cap Screws Set Screws
Fastener Alloy Alloy Stainless Alloy
Size Steel Steel Steel Steel
5/16” 33 - 35 27 - 30 14 - 16 18 - 20
(24 - 26) (20 - 22) (10 - 12) (13 - 15 )
3/8” 54 - 61 33 - 37 20 - 23 30 - 34
(40 - 45) (24 - 27) (15 - 17) (22 - 25)
1/2” 122 - 136 - 43 - 49 68 - 75
(90 - 100) (32 - 36) (50 - 55)