FRBH, FRBHX AND FRBHS USER INSTRUCTIONS ENGLISH 71569178 10-04
Page 42 of 54
®
7 FAULTS; CAUSES AND REMEDIES
FAULT SYMPTOM
Pump overheats and seizes
⇓⇓
Bearings have short life
⇓⇓
Pump vibrates or is noisy
⇓⇓
Mechanical seal has short life
⇓⇓
Mechanical seal leaks excessively
⇓⇓
Pump requires excessive power
⇓⇓
Pump loses prime after starting
⇓⇓
Insufficient pressure developed
⇓⇓
Insufficient capacity delivered
⇓⇓
Pump does not deliver liquid
⇓⇓
PROBABLE CAUSES POSSIBLE REMEDIES
A. System troubles
l
l
Pump not primed.
l
l
l
l
Pump or suction pipe not completely filled with
liquid.
Check complete filling. Vent and/or prime.
l
l
l
l
Suction lift too high or level too low.
l
l
l
l
Insufficient margin between suction pressure and
vapour pressure.
Check NPSHa>NPSHr, proper submergence,
losses at strainers/fittings.
l
l
l
Excessive amount of air or gas in liquid. Check and purge pipes and system.
l
l
l
Air or vapour pocket in suction line. Check suction line design for vapour pockets.
l
l
Air leaks into suction line. Check suction pipe is airtight.
l
l
Air leaks into pump through mechanical seal,
sleeve joints, casing joint or pipe plugs.
Check and replace faulty parts.
CONSULT FLOWSERVE.
l
l
Foot valve too small. Investigate replacing the foot valve.
l
l
Foot valve partially clogged. Clean foot valve.
l
l
l
l
Inlet of suction pipe insufficiently submerged. Check out system design.
l
l
l
Speed too low. CONSULT FLOWSERVE.
l
Speed too high. CONSULT FLOWSERVE.
l
l
l
Total head of system higher than differential head
of pump.
l
Total head of system lower than pump design
head.
Check system losses.
Remedy or CONSULT FLOWSERVE.
l
Specific gravity of liquid different from design.
l
l
l
Viscosity of liquid differs from that for which
designed.
Check and CONSULT FLOWSERVE.
l
l
Operation at very low capacity. Measure value and check minimum permitted.
Remedy or CONSULT FLOWSERVE.
l
l
l
Operation at high capacity. Measure value and check maximum permitted.
Remedy or CONSULT FLOWSERVE.