FAULT SYMPTOM
Pump overheats and seizes
⇓⇓
Bearings have short life
⇓⇓
Pump vibrates or is noisy
⇓⇓
Mechanical seal has short life
⇓⇓
Mechanical seal leaks excessively
⇓⇓
Pump requires excessive power
⇓⇓
Pump loses prime after starting
⇓⇓
Insufficient pressure developed
⇓⇓
Insufficient capacity delivered
⇓⇓
Pump does not deliver liquid
⇓⇓
PROBABLE CAUSES POSSIBLE REMEDIES
l
l
Improper installation of bearings (damage during
assembly, incorrect assembly, wrong type of
bearing etc).
Check method of assembly, possible damage or
state of cleanliness during assembly and type of
bearing used. Remedy or CONSULT
FLOWSERVE, if necessary.
l
l
Damaged bearings due to contamination. Check contamination source and replace damaged
bearings.
C. MOTOR ELECTRICAL PROBLEMS
l
l
l
l
Wrong direction of rotation. Reverse 2 phases at motor terminal box.
l
l
Motor running on 2 phases only. Check supply and fuses.
l
l
l
Motor running too slow. Check motor terminal box connections and voltage.