Flowserve NM Uživatelský manuál Strana 16

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 48
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 15
NM USER INSTRUCTIONS ENGLISH 71576289 - 11/09
Page 16 of 48
The alignment will be definitive only
after pipework connection (see § 4.5.1).
If necessary, improve the machine alignment:
Complete unit mounted on common base plate:
The machines are first aligned accurately in our
workshops. Usually, any misalignment observed on-
site is due to a wrong adjustment under the base
plate (disturbed during transport or because of
forces exerted by the pipework). It is only necessary
to rectify the adjustment under base plate. If it
proves to be insufficient, modify the motor and the
pipeworks adjustment.
Pump and motor mounted on individual base
plates:
Machines are (or must be) first mounted on their
own base plate in the workshop. Once the pump is
set, it will be regarded as the fixed piece. Any
alignment necessary shall be carried out on the
motor.
Never connect the electric motor
before the setting has been completely finished.
4.5 Piping
The user must verify that the equipment is
isolated from any external sources of vibration.
Protective covers are fitted to the
pipe connections to prevent foreign bodies entering
during transportation and installation. Ensure that
these covers are removed from the pump before
connecting any pipes.
4.5.1 Suction and discharge pipework
The dimensions of the pipes do not directly depend
on suction and discharge diameters of the pump:
a) First, choose a flow speed < 2 m/s at suction,
and about 3 m/s at discharge.
b) Take into account the available NPSH, which
must be superior to the required NPSH of the
pump.
Never use pump as a support for
piping.
Do not mount expansion joints in
such a way that their force, due to internal pressure,
may act on the pump flange.
Maximum forces and moments allowed on the pump
flanges vary with the pump size and type.
These external strains may cause misalignment, hot
bearings, worn couplings, vibrations and the
possible failure of the pump casing.
When designing the pipes (§ 4.5.2.1, § 4.5.2.2, §
4.5.3.1) take necessary precautions in order not to
exceed maximum allowed strains.
Forces and moments applied to the pump flanges
must never exceed the values shown in the table
below:
Forces (daN) Moments (m.daN)
Pipes
layout
DN
flanges
F
Y
F
Z
F
X
F
M
Y
M
Z
M
X
M
32 30 40 35 60 23 27 34 49
40 30 40 35 60 23 27 34 49
50
40 50 45 80 27 30 37 54
65
50 68 58 102
30 33 40 60
80 60 75 70 120
32 36 44 65
100 80 100
90 160
36 41 50 74
125 100
125
110
200
44 52 63 92
150 120
150
135
240
53 62 75 110
200 162
200
180
314
69 79 97 144
250 200
250
224
390
86 99 121
180
300 242
300
269
470
129
148
182
267
350 300
375
336
586
192
221
270
400
Vertical pipework
perpendicular
to the shaft
450 363
450
403
703
255
294
359
528
32 40 30 35 60 23 27 34 49
40 40 30 35 60 23 27 34 49
50 50 40 45 80 27 30 37 54
65
68 50 58 102
30 33 40 60
80 75 60 70 120
32 36 44 65
100 100
80 90 160
36 41 50 74
125 125
100
110
200
44 52 63 92
150 150
120
135
240
53 62 75 110
200 200
162
180
314
69 79 97 144
250 250
200
225
390
86 99 121
180
300 300
242
269
470
129
148
182
267
350 375
300
336
586
192
221
270
400
Horizontal pipework
perpendicular
to the shaft
450 450
363
403
703
255
294
359
528
Ensure piping and fittings are flushed
before use.
Ensure piping for hazardous liquids is
arranged to allow pump flushing before removal of
the pump.
Zobrazit stránku 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 47 48

Komentáře k této Příručce

Žádné komentáře