Flowserve MD-200 Series Durametallic Uživatelský manuál Strana 5

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 8
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 4
5
3 Seal Barrier Gas Supply
The standard MD-200 seal design, using #22 carbon rotor faces, is
engineered to operate with non-humidied gas supplied to the seal
chamber at a consistent pressure 2 bar (25 psig) above the maximum
vessel pressure. Nitrogen gas is the barrier uid of choice. The gas to be
used, maximum vessel pressure, shaft speed, temperature, equipment
and shaft size must be specied when the seal is ordered.
Note: MD-200 seal designs using #5 carbon rotor faces, still require a
conditioned or humidied barrier gas. Nitrogen gas, humidied with a
polar compound (water), is the barrier uid of choice.
4 MD-200 Seal Piping
4.1 Install piping for the clean nitrogen to the canister tap. A lter,
pressure regulator, ow meter, check valve and pressure indicator
are recommended.
Note: A conditioner or humidier is recommended when using MD-200
with #5 Carbon rotor faces.
4.2 Bearings (optional) have been pre-lubricated during seal assembly.
Recommended Piping for Dual Conditioned Gas Seal
Figure 2
Check
Valve
N
Source
Pressure
Regulator
Pressure
Indicator
Bypass
Humidier
(optional: use only with
#5 carbon rotor faces)
Flow
Meter
Barrier
Gas
Inlet
2
Filter
Zobrazit stránku 4